top of page

Cables &
connectivity

We provide all the solutions for connecting and wiring your cathodic protection solutions.

Thanks to our innovative solutions, benefit from substantial time savings as well as savings on the purchase of equipment.

Junction box

Placed at each area of the structure, the junction box allows for relaying with the cathodic protection controller while reducing the quantity of cable by 30%.

 

These boxes also make it easier to identify the input and output cables for each zone.

01_ BLUESPINE perfect adaptability

Great adaptability

Perfect adaptability whatever:

  • The size of the area to be protected,

  • The number of connections,

  • The number and type of measurements to be carried out.

03_BLUESPINE reliability and robustness

Reliability and robustness

  • Double membrane cable gland plate relieves strain and protects cables.

  • Moisture and dustproof connectors (IP66).

BLUESPINE time and money saving

Time and money saving

  • 30% reduction in the total quantity of cables.

  • Simplification of implementation.

04_ BLUESPINE Easy and quick installation

Ease and speed of installation

  • Tool-free connection technology: 60% time saving compared to a traditional connection.

  • Prevention of the risk of wiring errors, in accordance with the recommendations of international standards.

XLPE-XLPE

Copper cables

Available in single-core and multi-core, we supply all the cables necessary for the installation of cathodic protection, in all the colors indicated by the standard.

Mono-core

Multi-core

XLPE-XLPE copper cables

​​Available in all the colors recommended by the international standards :

  • Red - anode power

  • Black - steel power

  • Blue - reference electrode measure

  • Yellow - other sensors measure

  • Grey - steel measure

Perfect

Waterproofing
 

Double insulation sheath

XLPE-XLPE:

 

  • Adaptability to all environments, even the most aggressive

  • Inside the structure (mortar or repair concrete): resistant to alkaline environments (pH13) and acid environments (pH2).

Robustness

  • Moisture resistance - prevention of copper corrosion and short circuit phenomena
  • Heat resistance - withstands prolonged exposure to high temperatures (100°C) without melting or warping

  • Mechanical resistance - resists traction, abrasion, repeated impacts.

Multi-core cable

Connect the PLC to the various junction boxes for the measuring circuit:

 

Customer benefits:

 

  • Savings: reduction in the quantity of cables (5 to 1)

  • Productivity gain

  • Particularly suitable for large works